Maximum rated speed: 2,3 m/s ; Minimum rated speed: 0,4 m/s
Tripping speed:
BI-DIRECTIONAL or SINGLE-ACTING:Minimum: 0,66 m/s Maximum: 2,72 m/s
ONLY SINGLE-ACTING (STAR LS):Minimum: 0,35 m/s Maximum: 0,65 m/s (Only single-actiong Star orders: Specify whether the overspeed governor is to be positioned upwards or downward)
Pulley Diameter: 200 mm ; Rope Diameter: 6 mm Ready for encoder positioning Overspeed contact included Remote tripping mechanism by electrical acting: 24, 48 or 190 VDC included Rope out protection included Rope slackening contacts included Protection plate (optional) Hardened groove (optional Encoder (optional)
According to the standards: EN 81-1 and EN 81-2
Tripping speed:
BI-DIRECTIONAL or SINGLE-ACTING:Minimum: 0,66 m/s Maximum: 2,72 m/s
ONLY SINGLE-ACTING (STAR LS):Minimum: 0,35 m/s Maximum: 0,65 m/s (Only single-actiong Star orders: Specify whether the overspeed governor is to be positioned upwards or downward)
Pulley Diameter: 200 mm ; Rope Diameter: 6 mm Ready for encoder positioning Overspeed contact included Remote tripping mechanism by electrical acting: 24, 48 or 190 VDC included Rope out protection included Rope slackening contacts included Protection plate (optional) Hardened groove (optional Encoder (optional)
Dirección de Contacto de Dynatech Polígono Ind. de Pina de Ebro Sector C, p-9 50750 Pina de EbroTel.: +34 976 165 860 Españainfo@dynatech-elevation.com® 2005 DYNATECH