Dynatech

Consulte nuestra web en diferentes idiomas:

 
OVERSPEED GOVERNORS STAR
STAR PLUS

Acting:
BI-DIRECTIONAL or SINGLE-ACTING

Maximum rated speed: 2,3 m/s ; Minimum rated speed: 0,4 m/s

Tripping speed:

  • BI-DIRECTIONAL or SINGLE-ACTING: Minimum: 0,66 m/s Maximum: 2,72 m/s
  • ONLY SINGLE-ACTING (STAR LS): Minimum: 0,35 m/s Maximum: 0,65 m/s
    (Only single-actiong Star orders: Specify whether the overspeed governor is to be positioned upwards or downward)

Pulley Diameter: 200 mm ; Rope Diameter: 6 mm
Ready for encoder positioning
Overspeed contact included
Remote tripping mechanism by electrical acting: 24, 48 or 190 VDC included
Rope out protection included
Rope slackening contacts included
Protection plate (optional)
Hardened groove (optional
Encoder (optional)

According to the standards: EN 81-1 and EN 81-2

Tripping speed:

  • BI-DIRECTIONAL or SINGLE-ACTING: Minimum: 0,66 m/s Maximum: 2,72 m/s
  • ONLY SINGLE-ACTING (STAR LS): Minimum: 0,35 m/s Maximum: 0,65 m/s
    (Only single-actiong Star orders: Specify whether the overspeed governor is to be positioned upwards or downward)

Pulley Diameter: 200 mm ; Rope Diameter: 6 mm
Ready for encoder positioning
Overspeed contact included
Remote tripping mechanism by electrical acting: 24, 48 or 190 VDC included
Rope out protection included
Rope slackening contacts included
Protection plate (optional)
Hardened groove (optional
Encoder (optional)

According to the standards: EN 81-1 and EN 81-2

ATI / LD-VA / M109A-3/ 11
  Overspeed governor STAR PLUS Operating and maintenance instructions Operating and maintenance instructions

Rated speed of the car (m/s):
Advisable governor tripping speed (m/s):
Selection of optional accessories:
Message:
manual2

manual2

Búsqueda en Dynatech:


Dynatech-Elevation Blog

Dirección de Contacto de Dynatech
Polígono Ind. de Pina de Ebro Sector C, p-9   50750 Pina de Ebro Tel.: +34  976 165 860  España info@dynatech-elevation.com ® 2005 DYNATECH